Dimensions
- Refer attached drawings for detail dimensionsand size.
RS485 Protocol
| Baudrate |
9,600 |
Data Bits |
8 |
| Stop Bits |
1 |
Parity |
None |
- Data Format (ASCII)
= STX + Xdeg + SP + Ydeg + ETB + Check Sum + $
- [SP+Ydeg] is skipped for Uniaxial.
- Check Sum : Substitute ASCII of each bytes for HEX and calculate by XOR.
- Commands (not case sensitive)
Carriage Return and Line Feed must be attached to end of commands.
e.g. #DATA+CR+LF
| #DATA |
Measure data once. |
| #READ |
Measure data continuously. |
| #STOP |
Stop measuring. |
| #INFO |
Get sensor information. |
| #ID{NO} |
Set ID to {NO}. |
| #SAVE |
Save settings |
- ID can be set within 0~80. (in HEX, plus B0 to ID : B0~FF)
- To complete ID set, set ID on ID set mode, power off and on again.
- Multiple sensors on parallel connection, can measure individual sensor data ; set individual sensor ID and send below command in HEX.
CR+LF is unnecessary in this case.
- Command : Sensor ID [B0~FF] + 05
e.g. (HEX) B1 05
Notes
- Specification changes after shipment will be charged for a fee, so be sure to order with the correct specifications.
- Ground connection is recommended in noise occurred environment.
- MEMS based inclinometer (tilt sensor) measure tilt (degree) by gravity. Check sensing directions before use.
- Check wiring connections before use.
- 12 months warranty is provided after released. Warranty provided only in case of using for designed purpose correctly.
- Specifications, design and components can be changed without prior notice to improve its performances.
|
 |