제품정보

JSENS-IN Technical Datasheet
  •  
  • JSENS-IN Technical Datasheet
  •  
  •  
  • High performance MEMS based inclinometer (tilt sensor)
  • Perfectly applicable with CANopen and SAE-J1939
  • Micro-Processor mounted for stable sensing and data processing
  • Customized specifications for applying various industry areas
  • CE / FCC / ROHS
  •  
  •  
  •  To respond CAN that becoming mainstream communication standard for mobile vehicles, new-generation sensor series which perfectly applicable for CANopen and SAE-J1939 are now released. Introduce the series of high reliable CANbus sensors exceed performances of current analog and serial communication.
  • General Specifications

    Item Specification Remark
    Measuring
    Range
    Uniaxial +/-1 ... +/-180 deg Settable
    Biaxial +/-5 ... +/-80 deg
    Accuracy 0.1 deg  
    Non-Linearity 1% FS  
    Response <0.1 sec  
    Output 0.5 ... 4.5Vdc  
    CANopen  
    SAE-J1939  
    Power Source 10 ... 30VDC  
    Current
    Consumption
    <30mA @24Vdc
    Operating
    Temp.
    -20 ... +85 celsius  
    Waterproof IP66  
    Mechanical
    Life
    Semi-Permanent  
    Dimensions W40 x D40 x H16mm  
    Weight 40g  
     
    • Uniaxial : Set freely within +/-1 ... +/-180 deg
      e.g. -30 ... +90 deg / 0 ... +120 deg
    • Biaxial : Each axis within +/-5 ... +/-80 deg

    • Measuring range fixed as maximum with CAN.
    • Dimensions are without mounting.

    Sensing Directions

    X-axis [Floor] X-axis [Wall]
    Y-axis [Floor] Y-axis [Wall]
     
    • Above images show sensing directions of JSENS-IN.












    Wiring Connections

     
    Axis Color Analog CANbus
    Uniaxial RED V+
    BLACK GND (COM)
    GREEN X+ CAN H
    Biaxial WHITE Y+ CAN L
    • JSENS series is designed for Delphi 1216-2833 plug. Harness can be ordered optionally for wiring.
    • Uniaxial doesn't use the white wire

    CAN Protocol

    • Bitrate : 500 kbps
    • Transmit Interval : 10㎳
    • Transmit Start : Automatically
    • Default COB ID (HEX) : 0x0A
    • Output data includes only angular data.
    • Refer each protocol manual for CANopen and SAE-J1939.





    Analog Data Descriptions



    • Deg. from Analog - Vdc output
       
      • Measuring Range : max range - min range
      • Output V Range : 4.5V - 0.5V = 4V
      • Zero Offset : 2.5V


      •  
    • e.g. Measuring range +/-90 deg, Output 3.5V,

    Ordering Code

     
    [1]
    • S
    • D
     
    • Uniaxial
    • Biaxial
    [2]
    • MV
    • CO
    • CJ
     
    • 0.5 ... 4.5Vdc output
    • CANopen protocol
    • SAE-J1939 protocol
    [3] Set measuring range
    [4]
    • F
    • W
     
    • sensing direction of [Floor]
    • sensing direction of [Wall]
    [5]
    • C
    • NC
     
    • Terminating Resistance (default)
    • Non-Terminating Resistance
    • Format : JSENS-IN- [1] - [2] - [3] - [4] - [5]

    • e.g. JSENS-IN-S-CO-180-F-C
      measuring range 180 means +/-180 deg



    •  
    • Options
      • Plug Harness : Delphi 1216-2833
      • COB-ID : settable within HEX 201...27F


    NOTES

    • Ground connection is recommended in noise occurred environment.
    • MEMS based inclinometer (tilt sensor) measure tilt (degree) by gravity. Check sensing directions before use.
    • Check wiring connections before use.
    • 12 months warranty is provided after released. Warranty provided only in case of using for designed purpose correctly.
    • Specifications, design and components can be changed without prior notice to improve its performances.
     

    Copyright ⓒ 2018 (주)다스. All rights Reserved